Allgemein

Phthalates
GC-MS Analysis of Phthalates: Comparison of GC Stationary Phase Performance

Abstract: Phthalates are ubiquitous in the environment and have attracted attention due to their potential adverse impact on human health. For this reason, detection and separation of phthalates has become a necessity.

Electronic Maintenance Indicators for Gas Filters

Restek’s electronic maintenance indicator is a monitoring device that warns you when planned maintenance for a gas filter is due.

Outfit Your Agilent MSDs with Restek® Chromatography Supplies

• High-Temp EI Filaments
• Fittings, Connectors, Nuts & Transfer Lines
• ETP Electron Multipliers
• Pump Oil, Cleaning Powders & More

Impact of GC Parameters on The Separation V

Part 5: Choice of Column Temperature
In parts 1, 2, 3 and 4 of this series we focused on the selection of stationary phase, column length, ID and the film thickness. Besides the column specific parameters, there are three non-column specific parameters that impact the separation. These are the type of carrier gas, its linear velocity and the temperature of the column. Here we look into the effects of temperature on separations as shown in Figure 1.

 

Impact of GC Parameters on The Separation IV

Part 4: Choice of Film Thickness

Impact of GC Parameters on The Separation III

Part 3: Choice of Column Length
In Part 1 and 2 of this series we focused on selection of stationary phase, and looked at different applications for using different internal diameter. Capillary columns are also available in different length. Here we look at the third parameter: column length as shown in Figure 1. What is the impact of column length on the separation? If length is changed, what do I have to do to get the results that I anticipate?

Impact of GC Parameters on The Separation II

Part 2: Choice of Column Internal Diameter
In Part 1 of this series we focused on how to select the stationary phase, which is one of the seven important parameters we need to understand (see Figure 1). Once the most interesting stationary phase is selected, the column dimensions must be considered. Here column length, diameter and film thickness are the key parameters. In this article we turn our attention to the column internal diameter and its relevance.

 

Impact of GC Parameters on The Separation I

Part I: Choice of the Stationary Phase
In this series, we will discuss the impact of different parameters on the actual separation. We will do this by discussing how they impact and then explain the impact by some practical examples. In GC there are seven important parameters that we can choose to get a separation. All parameters have an impact and selection of a certain parameter has an impact on the separation.

 

 

How to Choose the Right Vial for Chromatography Applications
GC Column Installation Made Easier with Extended Reducing Nuts for the Agilent® Split/Splitless Inlet

Seiten